Boiler error code F75 — what should you do?

Your boiler no longer detects water flow properly. Usually the pump or the pressure sensor.

Error codes

How F75 shows up

  • The boiler shuts down shortly after starting
  • Code F75 appears when heating is requested
  • An unusual pump noise (grinding, whistling)
  • Heating works intermittently
  • Hot water keeps working normally

What error code F75 means

  • Blocked circulation pump — the rotor no longer turns freely, often after a long period of inactivity (end of summer).
  • Air in the system — an air pocket prevents the water from circulating properly.
  • Insufficient water pressure — the gauge shows a value too low for the pump to be detected as running.
  • Faulty differential pressure sensor — the boiler no longer receives the flow signal, even though water is circulating fine.
  • A system valve closed by mistake — after recent work or a service visit.

What you can safely check yourself

1

Check the pressure

The boiler gauge should read between 1 and 2 bar when cold. Below 1 bar, topping up is likely needed.

2

Check that the system valves are open

The valves on either side of the boiler or the pump should be in the open position.

3

Code still there? Call a professional

An F75 that doesn't clear after topping up often comes from the pump itself or the sensor — a licensed technician needs to step in.

Which brands does this code apply to?

This code is used as-is on Vaillant and Bulex boilers, two brands that share the same technical platform. On Junkers, Viessmann, Atlantic and Remeha boilers, an equivalent fault shows under a different code — our technician identifies the fault on site, whatever the brand.

A clear price, no surprises

A fixed 35 € call-out fee in Brussels, Wallonia and Flanders. The repair price is given to you before any work starts. Free, no-obligation quote on 0488 02 77 07.

Frequently asked questions about code F75

Can I top up the heating system myself?

Yes, if your boiler has an accessible filling valve and your installer has already shown you how. If in doubt, it's best left to a professional: topping up incorrectly can introduce more air.

Why does F75 come back after every top-up?

If pressure keeps dropping, there's probably a leak somewhere in the system — expansion vessel, radiator or fitting. Topping up is then just a patch, not a fix.

Is a blocked pump serious?

No, it's a common fault after the summer shutdown and usually quick to fix: a manual unblock of the rotor is often enough, otherwise the pump is replaced.

How much does replacing a circulation pump cost?

The price depends on the pump model. Our technicians quote on site after diagnosis, before any work begins.

Can't find your code? Call us, we'll help.

0488 02 77 07
Free quote — Reply within 30 min

Get your quote in 60 seconds

Urgent? 0488 02 77 07 or WhatsApp

Step 1 of 2Timing

When would you like us to call you?

Which region are you in?

Flat €35 travel chargeFree quoteCallout 7 days a week
CallWhatsAppFree quote